− | 911 HTTP Gateway is necessary in cases where a processor requires a dedicated connection to the host | + | 911 HTTP Gateway is necessary in cases where a processor requires a dedicated connection to the host, because such a scheme is not scaleable when a large number of clients is accessing the host from the same server. |
An example of usage is [[CreditLine_ValueLink_Setup|ValueLink Gift Card Processor]] | An example of usage is [[CreditLine_ValueLink_Setup|ValueLink Gift Card Processor]] | ||
Revision as of 16:37, 17 August 2006
This article is part of the Payment Processing Software Library |
|
Get it... | |
Install it... | |
Connect to it... | |
Set it up... | |
Learn to use it... | |
→ Manual & User Guide | |
Fix it... | |
→ Errors & Troubleshooting | |
Get Help... | |
More Info ... | |
See also... | |
CreditLine Payment Processing Software Installation. This site can also be reached at http://docs.911software.com
→ Looking for better rates? Get a Free Credit Card Processing Cost Comparison!
Overview
911 HTTP Gateway is necessary in cases where a processor requires a dedicated connection to the host, because such a scheme is not scaleable when a large number of clients is accessing the host from the same server. An example of usage is ValueLink Gift Card Processor
Requirements
Installation
- Download Tomcat 4.x
- Install Tomcat 4.x
- Unzip the 911 HTTP Gateway Files (CCVPlex.zip) into the tomcat webapps directory. Use the folder names when unzipping. This will create the CCVPlex folder under the tomcat webapps directory.
- Copy CCVPlex.properties file to the root directory.
- Open the CCVPlex.properties file and change the properties using the values provided by ValueLink.
- Restart tomcat.
CreditLine 911 HTTP Gateway Setup
Enter CreditLine Connection Setup Dialog